<br />Building Permit Submittal Requirements <br /> <br />Erosion Control Plan <br /> <br />Erosion control plan requirements - may be identified on certificate of survey. <br /> <br />A. Silt fence - a silt fence shall be identified on the erosion control plan. The silt fence shall <br />be located along the front yard (3 feet from the curb or behind the sidewalk) along <br />existing developed yards, and where needed for erosion control as determined by the <br />City's consulting firm reviewing the plan. <br /> <br />B. Rock driveways - A rock driveway shall be identified on the erosion control plan. The <br />rock driveway shall be constructed of CAl/CA2 Course Aggregate 1-2" rock - 6" deep <br />per MPCA Manual (see Appendix). <br /> <br />C. Inlet protection -Inlet protect meeting City standards must be installed around any catch <br />basin inlet or flared end inlet on the property. <br /> <br />D. Rock check dams - Rock check dams shall be required along swales and concentrated <br />points of overland flow discharge where grades exceed 3%. <br /> <br />Review of Erosion Control Plan <br /> <br />The proposed erosion control plan will be reviewed by a consulting engineering firm <br />hired by the City to verify compliance with City standards. The cost of the erosion control plan <br />review is included in the grading review fee. <br /> <br />6 <br />