Loading...
HomeMy WebLinkAbout3 - Rio Gran Site Planince 1857 Hastrngs MINNESOTA To: Planning Commission Planning Commission Memorandum From: Justin Fortney, City Planner Date: July 8, 2024 Item: Site Plan — 2024-14 — Rio Gran Trucking — 601 31St St E Planning Commission Action Requested: The Planning Commission is asked to review the proposed site plan and make a recommendation to the City Council. Background Information: In February, HEDRA (Hastings Economic Development and Redevelopment Authority) and Richard Beskau with Rio Gran Express LLC entered into a purchase agreement for the property sale. The use of the site is for a second location for their business at 12260 Margo Ave S, which has been operating for the past 23 years. This site will feature a building to house their semi -trucks indoors, additional indoor parking spots for rent, a designated area for light maintenance work on their own semi -trucks, outdoor parking for semi -trailers, and an office to manage operational tasks. Site Plan Review Comprehensive Plan Classification The 2040 Comprehensive Plan designates this area as Industrial. Zoning Classification The subject property is zoned 1-1 Industrial. Adjacent Zoning and Land Use Direction Existing Use Zoning Comp Plan North Light Industrial 1-1 Industrial East Light Industrial 1-1 Industrial South (31St) Residencial R-3 Medium Density Residential West Light Industrial 1-1 Industrial Existing Condition The site is mostly flat, unimproved, grass, with a few trees in the rear. Building Setbacks Setbacks in the 1-1 Industrial district are determined at the time of site plan review. The proposed building setbacks are adequate with the building being centered and surrounded with parking and maneuvering area. Vehicular Access and Circulation The site is laid out to maximize maneuvering area for semi -trailers. There are two entrances to also aid in maneuverability. Parking The main purpose of the building is for parking of semi -trucks. The project proponents indicate that passenger vehicles would likely be driven to the site and switched with the semi -trucks in the building. There are only four passenger vehicle spaces delineated on the site. Parking standards for this sized building would require about 22 spaces if it were used for something other than parking. A proof of parking plan shows how the full parking requirements can be met if the use were to change and semi -trailer parking was changed to passenger vehicles. Architectural Standards Architectural standards require 65% class 1&2 materials, with at least 25% being class 1 for elevations visible from the street. Class 1 includes (brick, stone, glass, etc.) and class 2 including materials meant to mimic class 1 materials and composite products. The proposed building fagade facing the street includes a lot of glass and some brick, which are class I materials. The class 11 materials used including burnished CMU block and Nichiha fiber cement Panels. Many of these materials wrap around to the west side of the building. The site plan shows an overheard door on the east side of the building but is not shown on the elevation drawings. Landscaping Based on the site size and amount of pavement, the zoning ordinance requires the following number of plantings, as proposed. A tree inventory was provided showing the only large trees were Siberian Elm, which are invasive. Type Required Proposed Trees 27 27 Shrubs 22 22 Lighting The proposed photometric plan shows light levels at the property lines to be below the limit of one foot-candle. Recommended Action: Approval of the site plan, subject to the following conditions: 1) Conformance with the Planning Commission Staff Report and plans dated July 8, 2024. 2) All disturbed areas of the property shall be stabilized with rooting vegetative cover to eliminate erosion problems. 3) Any uncompleted site work must be escrowed at 125 percent of the estimated value prior to issuance of a certificate of occupancy. 4) The perimeter of the site must have erosion control, as approved by the City Engineering Department. 5) The City Engineering Department must approve any required drainage plan. 6) Approval is subject to a one-year Sunset Clause; if significant progress is not made towards the proposal within one year of City Council approval, the approval is null and void. 7) A right-of-way permit must be issued for any work in the right-of-way. 8) No outdoor unscreened storage is allowed. Attachments: • Aerial Photograph • Elevation Drawings • Site Plan aelTWIA _lam lin trx. m*. Q l 1 111 IIII}IIHI nnnnr" I III1 11 �ualmutfll 111 •. ca tMYNl+m®�' "I"A I1�11�1 !J►ilm JI -.1orON5[ ± Rear East LOT 4 0' 2I3M3S OAd „ 8 NVS GRAPHIC SCALE 20 0 10 20 40 (1N FEET) 11N= 20 FT NOTE: UTILITY CONNECTIONS AND ELEVATIONS WILL NEED TO BE VERIFIED AND ADJUSTED IN THE FIELD. LOT 3 LOT 2 VICE 838 837 836 835 6: 1 CsIN f�FlLTRATION BASIN OF e?e APS 0csi 1.4Z B61$ 'EXISTING Dw4 HY ANT GAS 5 1? TBC8455 °? 9 GAS " fir 0 �`\ f �, ' PV k •ANITAR- � DUS PARj 71. . •E�' ER TENSvn �� " ER T• 11� \iii Alpit 1111, � 3.00' \IL \ 1 N VERTICAL DUAL WALL 10,000 GALLON FUEL 843.4rIANK E• 39.62' h e3 h h n,�e 11117.00' • 843.610% 0 • • 5.66%842 1 I BOLLA'DS co , 1� 845 I05 •=.—i---,,.----- .4,0SUR : ABLE/DRI n*VER CONC0 C)‘'' oo a oUA (TO FUEItTANK) r8, i,4q. ALUMII�JM FENCE T� • AL'NG CONCRETE PATI( . > 6 PARKING SPOTS LOCATED INSIDE 842.. 4 6 .25 if 6.00 Li fEE6 90.00' 1 . 50 842.9i.4 5.3425 :w FK 2 725 843.00 FIRST ELEV:: LOOK 44.50 84 I I c4.00' 843.10 . • a .23%- 844.22lay 7.00' 8gi:6. 0 " er. 844.81 1 k5k 0 +0 :g 1O • hh• 90 .00' y A 24.00' �N7l1.. cgg " A.49 .33 X02 7 • 0' .: p• 8gg -.. .fig 4 .:r a �_. ,•..e �_ 01' >n ..i.843.30 % �Cd. '.6 843. , % % 1.14%48+. RO > .69 838.19 GAS 0 _� S 31ST STREET EAST • TRAIL RECONSTRUCTION NOTES: PRIOR TO PLACEMENT OF BITUMINOUS FOR MILLED AND AGGREGATE SURFACE SHAPED BITUMINOUS. AGGREGATE AND BITUMINOUS co BITUMINOUS IN THE DRIVE/TRAIL CROSSING • HOURS IN ADVANCE OF SURFACING TO ALL ro HASTINGS INDUSTRIAL PARK NO. 6 LOT 7 RIVE ACCESSES, THE AREAS OF THE TRAIL SHALL BE SAW CUT, JOINTS 0 MEET CITY REQUIREMENTS FOR CROSS SLOPE (2%) AND DEPTH OF EPTH THROUGH THE DRIVES SHALL BE THICKENED WITH THE DEPTH OF 0 LESS THAN 4" THICK. CITY INSPECTORS SHALL BE NOTIFIED 24 FOR INSPECTION PRIOR TO SURFACING. SITE ZONING INFORMATION - CURRENT ZONING: INDUSTRIAL -SITE ADDRESS: (TBD) 31ST STREET HASTINGS, MN 55033 -PARCEL ID: 193200502060 -LOT 6 - BLOCK 2 - HASTINGS INDUSTRIAL PARK NO 6 BASE SITE AREA: TOTAL BUILDING SQUARE FOOTAGE PROPOSED: TOTAL DRIVE/PARKING SURFACING: TOTAL GREEN SPACE: 43,420 SQ FT (1.00 ACRES) 9,385 SQ FT (0.22 ACRES) 27,176 SQ FT (0.62 ACRES) 6,859 SO FT (0.16 ACRES) NPDES PERMIT CRITERIA: TOTAL DISTURBED AREA = 0.99 ACRES < 1.0 ACRES - PERMIT NOT REQUIRED TOTAL NEW IMPERVIOUS - 0.83 ACRES < 1.0 ACRES - PERMANENT STORM WATER TREATMENT NOT REQUIRED OWNER AND CONTRACTOR SHALL STILL COMPLY WITH STATE AND CITY STANDARDS FOR STORMWATER PROTECTION INCLUDING MONITORING AND MAINTENANCE TO KEEP CONSTRUCTION DEBRIS AND SEDIMENT WITHIN THE SITE - MINIMUM % OF LANDSCAPE AREA > 10% (PROVIDING 16%) - LANDSCAPING REQUIREMENTS ONE TREE PER 4000 SQ FT IMPERVIOUS SURFACE (10 REQUIRED - 8 MUST BE DECIDUOUS) ONE TREE PER 50 FEET OF LOT PERIMETER (4 REQUIRED IN BOULEVARD) 17 TOTAL REQUIRED ONE SHRUB PER 40 FEET OF LOT PERIMETER - 22 REQUIRED SCREENING OF THE 31ST STREET PARKING LOT TO ACHIEVE 70% OPACITY. 4 DECIDUOUS TREES MAY BE REQUIRED AS PART OF THE TREE PRESERVATION PLAN SUBMITTED FOR THIS PROJECT. TOTAL PLANTINGS: 29 DECIDUOUS TREES (27 IF PLAN ACCEPTED). 2 CONIFEROUS TREES 22 SHRUBS - DECIDUOUS PLANTINGS SHALL BE A MIX OF HARD MAPLE, HYBRID ELM, LOCUST, LINDEN AND OAK. (1.5" CALIPER MEASURED 6" HIGH) - CONIFEROUS PLANTINGS SHALL BE BLUE SPRUCE OR FRASER FIR (6' TALL) 4 -SHRUBS SHALL BE A MIX OF DOGWOOD, FORSYTHIA, NINEBARK AND VIBURNUM (18" TALL) - DEVIATION FROM SPECIES LISTED SHALL BE APPROVED BY THE CITY OF HAS11NG FORESTRY DIVISION - 651-480-6177 - EXTERIOR UGH11NG - 155.53.5 - PHOTOMETRIC LIGHTING PLAN (PENDING) APPENDIX A - OFF STREET LOADING - PROVIDED WITHIN THE LOT APPENDIX B = REQUIRED PARKING SPACES - SHOP SPACE - 1 PER 500 SQ FT = 16 REQUIRED OFFICE - 1 PER 300 SO FT = 6 REQUIRED 22 TOTAL PARKING SPACES REQUIRED (22 PROVIDED) TRASH WILL BE LOCATED INSIDE THE BUILDING WITH CANISTERS SET OUTSIDE ON PICKUP DAYS WATER SERVICE CONNECTION NOTE: F&I 6" WET -TAP AND SLEEVE TO EXISTING 12" PUBLIC WATERMAIN. F&I 50 LF 6" PVC C900 SANITARY SEWER CONNECTION NOTE: F&I 6" SADDLE TO 8" MAIN. F&I 6" PVC SCHEDULE 40 OR SDR 26 SANITARY SEWER LINE TO THE BUILDING. CLEANOUTS SHALL BE INSTALLED AT MAXIMUM INTERVALS OF 100 FEET AND AT BENDS OR AS REQUIRED BY STATE/CITY BUILDING CODE. MINIMUM SLOPE SHALL BE 2%. PROVIDE MARKER POSTS FOR PROTECTION OF ALL CLEANOUTS. F&I 79 LF 6" PVC 0 2.00% INV UP:828.01 INV DOWN:826.43 WM SAN STORM OVHI U.E. TEL GAS WAT om000000mo 0 0 X 1060.00 X 1060.00 2.09% duo WATER HYDRANT & GATE VALVE SANITARY MANHOLE STORM MANHOLE & CATCHBASIN SIGNS GAS VALVE COMMUNICATIONS BOX ELECTRIC POLE LIGHT POLE TREE MAJOR CONTOUR MINOR CONTOUR WATERMAIN SANITARY SEWER STORM SEWER OVERHEAD ELECTRIC ONES UNDERGROUND ELECTRIC LINES UNDERGROUND COMMUNICATIONS UNE RAILING, CHAINUNK FENCE GAS UNE WATER SERVICE DRAIN TILE / SUBDRAIN PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR EASEMENT LINE RETAINING WALL BUFFERYARD UNE BITUMINOUS SURFACING CONCRETE SURFACING AGGREGATE SURFACING BUILDING BOULDER OR BIG BLOCK TRANSITION GARDEN PROPOSED BITUMINOUS SURFACING PROPOSED CONCRETE SURFACING PROPOSED BOULEVARD TREE SILT FENCE (PER ROCH. STD. PLATE 7-01) GRADING UMITS EXIS11NG SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED SLOPE INLET BARRIER (PER ROCH. STD. PLATE 7-05) PROPOSED EROSION CONTROL BLANKET (PER MNDOT 3885 CAT. 3N) ROCK CONSTRUCTION ENTRANCE (PER ROCH. STD. PLATE 7-06) RIP RAP (PER MNDOT 3133D) I HEREBY CERTIFY THAT THIS PLAN. SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERMSION AND THAT I AM A DULY UCENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. ARK R WELCH DATE 6/14/24 NEC NO. 42736 DATE: 5/15/2024 Prepared For: RIO GRAN EXPRESS 12260 MARGO AVE HASTINGS, MN 55033 FILE NO.: 24-144 BASE G-Cubecd, 14070 Hwy 52 S.E. Chatfield, MN 55923 ENGINEERING SURVEYING PLANNING Ph. 507-867-1666 Fax 507-867-1665 www.ggg.to DESIGNED ADB DRAWN ADB CHECKED MRW REVISED BY DATE PRELIMINARY ADB 5/29/2024 RESUBMITTAL MRW 6/14/2024 RESUBMITTAL ADB 6/24/2024 CITY OF HASTINGS DAKOTA COUNTY RIO GRAN EXPRESS SITE/GRADING PLAN BENCHMARK: FIRE HYDRANT APPROXIMATELY 30 FT WEST OF THE SW CORNER OF THE PROPERTY. TRH ELEV:849.20 SHEET 1 OF 1 SHEETS