HomeMy WebLinkAboutX-C-01 (a) Intek Plastics - 1000 Spiral Blvd. Site Plan Approval
City Council Memorandum
To: Mayor Fasbender and City Council From: Justin Fortney, City Planner Date: October 17, 2022 Item: Site Plan – Intek Addition – 2022-52– 1000 Spiral Blvd.
Council Action Requested: Review and act on the attached resolution. A simple majority is necessary for action. Background Information:
The applicants are proposing to construct an addition onto the Intek Plastics building with related improvements The Purchase Agreement for the eastern city owned parcel included in the site plan will
be considered at the November 7th City Council meeting. The eastern property does not
contain any building improvements but is necessary for stormwater drainage and a potential future roadway access. HEDRA recommended approval of the sale at its September 8, 2022 meeting.
Please see the attached Planning Commission memo for further information.
Financial Impact: N/A
Advisory Commission Discussion:
The Planning Commission reviewed the proposal on October 10, 2022 and voted 7-0 to recommend approval. Council Committee Discussion:
N\A Attachments:
• Resolution - Site Plan Approval
• Planning Commission Staff Report from October 10, 2022
X-C-01 (a)
HASTINGS CITY COUNCIL
RESOLUTION NO._________ A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF HASTINGS GRANTING SITE PLAN APPROVAL FOR
EXPANSION OF THE INTEK PLASTICS BUILDING AT 1000 SPIRAL BOULEVARD Council member _______________________ introduced the following Resolution and ___________________ moved its adoption:
WHEREAS, Intek Plastics has petitioned for Site Plan approval to construct a 60,200 Sq. Ft. addition onto the existing building generally located at 1000 Spiral Boulevard, legally described as Lot 1, Block 1, and lot 2, Block 1, except the south 520-feet thereof, all of HASTINGS INDUSTRIAL ARK NO 3 ADDITION, Dakota County, Minnesota; and
WHEREAS, on October 10, 2022, review was conducted before the Planning Commission of the City of Hastings as required by state law, city charter, and city ordinance; and WHEREAS, the Planning Commission recommended approval of the site plan to the City Council, subject to the conditions contained in this resolution; and WHEREAS, The City Council has reviewed the request and concurs with the recommendation of the Planning Commission.
NOW THEREFORE BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF HASTINGS AS FOLLOWS: That the City Council hereby approves the site plan as presented to the City Council
subject to the conditions: 1. Conformance with the plans submitted with the Planning Commission Staff Report
dated October 10, 2022
2. All disturbed areas on the property shall be protected to eliminate erosion control
problems.
3. Approval of a building permit.
X-C-01 (a)
4. Approval is subject to a one-year Sunset Clause; if significant progress is not made
towards the proposal within one year of City Council approval, the approval is null
and void.
5. The City Engineering Department must approve the grading, drainage, and erosion
control plan and related conditions for the proposed site and adjacent areas
impacted by the proposal.
6. The City Forester must approve the proposed tree planting species of the
landscaping plan.
7. The 3.1 acre city owned lot to the east of the existing site must be purchased by the
applicant for the current proposal.
Council member __________________ moved a second to this resolution and upon being put to a vote adopted by _____ present.
Ayes: ____ Nays: _____ Absent: ______
ATTEST: _______________________________ Mary Fasbender
Mayor _______________________________ Kelly Murtaugh
City Clerk
I HEREBY CERTIFY that the above is a true and correct copy of resolution presented to and adopted by the City of Hastings, County of Dakota, Minnesota, on the 17th of
October, 2022, as disclosed by the records of the City of Hastings on file and of record in
the office. _______________________________
Kelly Murtaugh
City Clerk (SEAL) This instrument drafted by: City of Hastings (JJF)
101 East 4th Street
Hastings, Minnesota 55033
X-C-01 (a)
To: Planning Commissioners
From: Justin Fortney, City Planner
Date: October 10, 2022
Item: Site Plan – Intek Addition – 2022-52– 1000 Spiral Blvd.
Planning Commission Action Requested
Review the proposed site plan and make a recommendation to the City Council.
Background Information
The applicants are proposing to add a 60,200 Square-foot addition onto the existing
building, parking lot addition, and related site improvements for drainage and
landscaping. The addition will be primarily for warehousing. Additional manufacturing
lines will be added in place of the relocated warehousing.
Comprehensive Plan
The property is guided Industrial within the 2040 Comprehensive Plan.
Zoning
The property is zoned I-1 – Industrial Park. Allowable uses include manufacturing,
warehousing and similar.
Existing Condition
The existing site was constructed in 1985 and has about 127,000 square-feet of
manufacturing, warehousing, and related office space.
Adjacent Zoning and Land Use
The following land uses abut the property:
Direction Use Comp Plan District Zoning District
North Veteran’s Park Park PI – Public Institutional
East Cranky Ape Auctions Industrial I-1 – Industrial Park
Planning Commission Memorandum
X-C-01 (a)
South Processing Industrial I-1 – Industrial Park
West Misc. Industrial Industrial I-1 – Industrial Park
Site Plan Review
Vehicular Access and Circulation
The existing site works well. There are three entrances on two streets. Changes
proposed include a parking lot addition to the east lot and improvements to the truck
access loop for the new loading docks. A future driveway is planned through the east lot
to Enterprise Avenue.
Building Setbacks
There are no prescribed minimum setbacks within the zoning district, however,
proposed setbacks are reviewed during site plan review for conformity with the area.
Proposed setbacks are within existing building setbacks, except to the rear. The rear
setback is proposed at 28-feet, which is 10-feet further than the much smaller adjacent
building to the west. Veteran’s Park is to the north. There is dense vegetation on the
south side of Veteran’s Park for screening, along what is proposed on site.
Required Parking
Parking minimums are met. The existing and proposed building sizes require 187 parking
spaces based on manufacturing and warehousing uses. A total of 190 spaces are
proposed after the additional 28 are constructed.
* Warehouse and Manufacturing: 1 per 1,000 SF (minimum one per employee)
Architectural Design
The applicant is proposing construction with a similarly textured precast panel as the
existing building. These panels fit the class II building material description. The western
façade is visible from the public street necessitating at least 65% class II materials and
25% Class I (glass, brick, natural stone). The applicants are proposing nearly 100% class
II with the textured precast panels on the western side and zero class I. The city has been
supportive of an increase of type II for a reduction of type I, when a façade is less visible
and particularly when it is an existing building addition. This western side is the most
visible as it is facing Millard Avenue, but is about 260-feet away with trees in-between.
The only type III material proposed is on the south elevation. It is a small area between
the two conjoined structures where the new structure extends about six-feet higher than
the existing building.
Landscape Plan
The proposed landscaping was significantly influenced by the City’s Tree Replacement
Guidelines. About 100 trees are proposed for removal in order to construct the addition
X-C-01 (a)
and grading for the drainage plan. Most of the significant trees that must be replaced are
Boxelder, Cottonwood, and Tatarian Maples. They are mostly in a few clumps on the
north and east parts of the site. They will be replaced with 111 3-inch caliper trees around
the site, which will improve the street scape and site screening.
Lighting Plan
Lighting locations will be similar to existing with automatic LED wall pack lighting on the
building and some LED pole lights in the parking lot to match existing.
Grading, Drainage, Erosion Control and Utility Plan Review
The drainage, grading and erosion control plan is being reviewed by the City Engineering
Department for compliance. The proposed site drainage will mostly be directed to a
proposed pond on the eastern lot for treating and infiltration. Some existing drainage
from Veteran’s Park may be directed to a treatment and infiltration pond south of the
water tower.
ATTACHMENTS
• Site Location Map
• Site Pictures
• Architectural Elevations
• Site Plan Documents (with updated tree planting list)
X-C-01 (a)
X-C-01 (a)
Vet’s Park
East Lot
Enterprise Ave Water Tower
X-C-01 (a)
X-C-01 (a)
215.0
28.45'27.98'
244.88'
245.13'
CO
N
C
P
A
D
12" RCP CULVERTS
PROPOSED
ADDITION
60,200 SF
2
8
0
.
0
0
2
8
0
.
0
0
215.00
65.74
9
3
.
5
1
62.80
56.96
A37.34
R40.00
A23.30
R15.00
NORTH
EXISTING 125,643 S.F
BUILDING
PROPOSED BITUMINOUS PAVEMENT - SEE DETAIL SHEETS.
KEYNOTES:
PROPOSED CONCRETE- SEE DETAIL SHEETS.
PROPOSED CONCRETE RETAINING WALL - SEE ARCHITECTURAL PLANS.
PROPOSED HEAVY DUTY CONCRETE - SEE DETAIL SHEETS.
PROPOSED SURFACES
EXISTING IMPERVIOUS SURFACES...........5.06 ACRES (220,644 S.F.)
PROPOSED IMPERVIOUS SURFACES.......1.75 ACRES(76,499 S.F.)
TOTAL IMPERVIOUS SURFACES............... 6.82 ACRES (297,143 S.F.)
TOTAL GREEN SPACE.................................6.60 ACRES (287,388 S.F.)
TOTAL LOT AREA.........................................13.42 (584,531 S.F.)
GREEN SPACE = 49% OF LOT
X-C-01 (a)
28.45'
133.87'
12 16
POSSIBLE FUTURE DRIVEWAY
3.50'
3.45'
18.00'18.00'
24.00'
2
8
0
.
0
0
R3.00A4.71
R3.00A4.71
20.00 6.
0
0
6
.
0
0
20.00
13
.
7
2
17.00
14
2
.
9
4
10
8
.
0
0
134.12'
14.00
50.00'
DRAINAGE EASEMENT
N89°58'41"W
50.00
S89°58'41"E 565.00
S89°58'41"E 515.25
PROPOSED BITUMINOUS PAVEMENT - SEE DETAIL SHEETS.
KEYNOTES:
PROPOSED B618 CURB AND GUTTER - SEE DETAIL SHEETS.
PROPOSED CONCRETE- SEE DETAIL SHEETS.
NORTH
F&I 4 C.Y CLASS IV RIP RAP
PROPOSED CURB CUT - SEE DETAIL SHEETS.
X-C-01 (a)
12" RCP CULVERTS
FF:841.08
FG:840.17FG:841.89
FG:841.32
FG:840.76
1.0%
6.1%
8
4
0
844845
843 842
845846
83
8
83
9
84
0
84
1
83
7
NORTH
ITEM DESCRIPTION UNITS
1 LF 150
ADDITIONAL BMP LIST
TOTAL ESTIMATED QUANTITY
2 INLET PROTECTION LF 3
3 EROSION CONTROL BLANKET SY 7,555
SEDIMENT CONTROL LOG
SEE SHEET 10
FOR DETAILED
GRADING PLAN.
SEE SHEET 10
FOR DETAILED
GRADING PLAN.
SE
E
S
H
E
E
T
9
X-C-01 (a)
CONC CURB AND GUTTER
CONC CURB AND GUTTER
CHAIN LINK FENCE
833
834835836
838 837
839840
840839
839
835 834
836 837 838
838
840
834833
833834835
836837838
839 841 841 840
EOF:839.50
EOF:837.50
DRAINAGE EASEMENT
N89°58'41"W50.00
S89°58'41"E 565.00
S89°58'41"E 515.25
NORTH
CUT VOLUME.............................................................33,408 C.Y.
FILL VOLUME................................................................3,507 C.Y.
EXPORT VOLUME.......................................................29,901 C.Y.
NOTES
● THESE VOLUMES USE A SWELL VALUE OF 1.2 AND A SHRINK FACTOR OF 0.9.
● TOP SOIL VOLUME IS UNKNOWN.
● THIS VOLUME INCLUDES EXCAVATION ON CITY PARCEL.
EXCAVATION QUANTITIES
FF:841.08
STORM WATER TREATMENT INFILTRATION POND
INSTALL SILT
FENCE AFTER
POND HAS BEEN
CONSTRUCTED.
SE
E
S
H
E
E
T
8
SEE SHEET 11
SEE SHEET 10
FOR DETAILED
GRADING PLAN.
X-C-01 (a)
BOTANICAL NAME COMMON NAMEKEYQTY SIZE
PROPOSED TREE SCHEDULE
4
10
3"Gleditsia triacanthos 'Street keeper'
3"Gleditisia triacanthos var. Inermis "Skycole"
39 3"Gymnocladus diocus
30 3"Populus tremuloides
1 3"Acer saccharinum 'Fall Fiesta Suger'
3 2"Prunus sargentii
13 3"Acer Rubrum
4 3"Ulmus x New Horizon
PROPOSED TREE REMOVAL SCHEDULE
Street Keeper Honey Locust
Skycole Honey Locust
Kentuckey Coffee Tree
Quaking Aspen
Autumn Radiance Maple
New Horizon Elm
Fall Fiesta Sugar Maple
Pink Flair Cherry
St. Croix Ameriican Elm
Amur Chokeberry
Bur Oak
Showy Mountain Ash
3"
2"
3"
2"
1 Ulmus mericana 'St. Croix'
1 Prunus Maa
1 Quercus macrocarpa
4 Sorbus decora
TURF ESTABLISHMENT
TOTAL TURF ESTABLISHMENT AREA TO BE SEEDED: 5.31 ACRES
GS
GT
GD
PT
AS
PS
AR
UN
UM
PM
QM
SD
X-C-01 (a)
12" RCP CULVERTS
NORTH
1130
1129
1052
1144
1149
1150
1139 1140
PT
1052
11431442
2
1104
1107
1106
11051
GT
1
GS
1111
11091108
4
GD
1138
1
UM
1148
1333
1132
1131
1135
11371136
1147
1146
11127
1125
1124
1108
1120
1121
1117
1123
1122
1113
1112
1110
1114
1126
1134
1119
1118
3
PS
1128
4
UN
PM
1145111611151141
1099
1100
1102
1101
3
PT
1096
1095
1097
10921091109010891088
1079
1086
1094
1093
3
PT1
GS
1076
1
AS
1073
3
GD1
QM
1071
1087
1078
1083
1084
1085
4
SD
1081
1075
1082
1080
4
GD
1072
4
GD
1
GS
1074
1
GT
1
AR
1
GS
1
1
GT
1
AR
AR
GT 6
PT
1 1077
3
PT
1098
1103
X-C-01 (a)
CONC CURB AND GUTTER
CONC CURB AND GUTTER
CHAIN LINK FENCE
EOF:839.50
EOF:837.50
DRAINAGE EASEMENT
N89°58'41"W50.00
S89°58'41"E 565.00
S89°58'41"E 515.25
NORTH
122712121207
4
1
GT
1
AR
1
AR
PT
1
AR
1
GT
3
GD
2
GD
3
GD 1
GT
AR
1
1220
1221
12221223
1225
1224
1
AR
1226
1
1
27
PT
1174 11
7
7
1
AR
11
7
2
11
7
3
11
7
5
11
7
6
11
7
8
11
7
9
18
0 AR
5
GD
1197
11641161
1162
1163
1165 1167 1168
1166
1
GT
11
6
9
11
7
0
11
7
1
1205
1204
1202
1203
1216
12061208
1209
1210
1213 1214
1211
1215
1
AR
1198
4
GD
1198
1201
10
GD
PT
AR
2
1154
1155
1146
1145
1144
114314421140
11531052
1052
1150
1156
1158
1
AR
1
1159PT
GS
11181117
11151111
1109
1108
1110
1114
1104
1121
1116
11071108
1106
1105
1138
1149GD
1
GT
1 4
1139
1141
1148
1131
1135 1147
1123 1125
1126
11241122
1134
1333
1132
1113 1120
113711361119
1098
1100
1112
1160
GT
1186
11871188
1189
1191
1190
1185
1229
1228
11831182
1184
1181
1193
1194
1217
1195
1196
1219
1192
1157
3
PS
1
PM
1
UM
4
UN
1127
1128
1127
1130
1129
X-C-01 (a)